Door Hardware Record Before an Access Upgrade
Legacy educational material. Product details and past offers may have changed. NERSA provides current project information.
Start with the opening, not the reader
An access-control upgrade can fail even when the credential reader and controller work correctly. The existing door may sag, the closer may be misadjusted, the latch may not align with the strike, or the proposed electrical hardware may conflict with an approved exit arrangement. A door hardware record helps owners, facility managers, architects, and service personnel describe current conditions before they select equipment. It is a field documentation guide, not a substitute for a door survey by qualified professionals or approval of a code-sensitive modification.
Identify each door consistently
Assign a door number that matches the latest floor plan and the names used by occupants. Record building, level, room or suite, exterior versus interior location, and the sides from which the opening is approached. Note whether it serves an emergency exit route, accessible route, tenant boundary, secure storage area, or public entrance. Photograph the door in the open and closed positions where authorized. Keep the date of the photographs and survey with the record so a future reviewer can tell whether a condition existed before the proposed project.
Observe the door and frame without forcing them
Record door material, frame type, approximate clear opening, number of leaves, visible damage, and environmental exposure. Observe whether the door closes fully and latches under normal operation, including at different traffic levels where practical. Watch for weather stripping, threshold problems, rubbing, or binding. Note hinges, closers, astragals, and panic or fire-exit hardware without disassembling them. If a door is fire-rated, capture any readable labeling rather than assuming the rating from appearance. Leave testing and disassembly to authorized personnel.
Describe the present hardware and user behavior
Write down visible manufacturer and model markings when readable, along with the current lock or exit-device function. Do not guess a part number if a label is obscured. Document what users actually do: pull a handle, push a bar, present a card, use a key, or request visitor entry. Record delayed closing, nuisance alarms, repeated propping, or accessibility complaints as observations. The same symptom may have a mechanical, electrical, administrative, or human-process cause. Avoid treating a new electronic lock as the automatic answer to a mechanical problem.
Map the operating states before selecting components
Ask the project team to describe normal business hours, locked hours, power loss, fire-alarm conditions, network interruption, and authorized override. Specify expected entry and exit behavior separately. Distinguish access on the secure side from free egress on the exit side. Do not assume that an electric strike, magnetic lock, electrified trim, or motorized exit device is interchangeable. Those technologies impose different requirements on wiring, power, hardware compatibility, and approved means of egress. A qualified designer should confirm the arrangement for the actual occupancy and applicable code.
Capture pathway and power questions
Record whether a door has existing raceway, a frame transfer, conduit, or unused cable, but do not presume undocumented wiring is suitable. Note the distance to the nearest controlled equipment cabinet and any exposed weather conditions. For electrified hardware, document the intended power source, door position monitoring, request-to-exit arrangement if used, and service access. Door loops and power-transfer hinges have different application and durability considerations. Where fire-rated openings are involved, unapproved drilling or alteration can affect the listing and must be reviewed in advance.
Include accessibility and life-safety stakeholders
Before design approval, identify who owns the accessibility, fire-protection, security, and building-code review. Check whether an automatic door operator, coordinated leaf hardware, special locking arrangement, or fire-alarm interface is present. Record the applicable authority having jurisdiction and any required inspection or permitting steps. Products advertised as compliant are not by themselves proof that a specific installation complies. Never defeat an exit device, bypass an emergency release, or modify a fire door simply to make the access system work.
Create acceptance checks tied to the original problem
At handover, compare actual operation with the approved sequence. Verify opening and latching, authorized access, denied-access behavior, door-held-open notification if specified, loss-of-power operation, and tested interfaces under the qualified test plan. Record who witnessed the tests, exceptions requiring correction, and maintenance responsibility. Keep as-built identifiers, approved drawings, model numbers, and training notes together. For technical context on matching door hardware to access-control upgrades, see NERSA’s door hardware retrofit guidance.
Copyable survey record
Door ID and location; survey date and observer; occupancy and door use; door and frame material; visible labels and hardware; current user sequence; reported issue; observed closing and latching condition; known wiring and power; fire and accessibility concerns; decision-maker; authority review status; proposed solution awaiting approval; acceptance-test owner; and outstanding questions. Update this record after changes instead of overwriting the original observations.
Coordinate hardware choices with permissions and exit requirements. Continue with Door Permission Worksheet for Property Teams and Exit-Door Review: Documents to Prepare.